TECHNOLOGY,
ENGINEERING &
PERFORMANCE

Dura-Glide 2000 and 3000 sliding door systems combine state-of-the-art microprocessor technology with advanced engineering to provide the safest, most dependable and highest performance door systems in the industry today.

The Dura-Glide 2000 and
3000 Series are the industry standard for smooth, reliable operation in every application from high-traffic retail locations to upscale professional and institutional settings.

Dura-Glide 2000 and 3000
are certified for Class 1 & 10 Clean Room applications.

All components are fully
tested and preassembled at the factory prior to shipping. Preassembled header components mean fast, trouble-free, installation at the job site.

  • Microprocessor controller continually monitors door position.
  • Proven reliability with long-lasting cast urethane load-bearing wheels provides smooth, trouble-free operation.
  • Adjustable anti-riser wheels locks each door in its track.
  • Fiberglass reinforced toothed drive belt prevents slippage and uneven closing.
  • Advanced motion sensors, Stan-Guard® threshold sensor, and doorway holding beam or Stan-Vision™ video sensors, provide complete protection at all times.
  • Weather Wise™ switch reduces opening widths on larger door systems to save energy in cold or hot weather.
  • Power-operated automatic sliding doors may be used as emergency egress doors because they “break-out” in the direction of egress.

The Dura-Glide 2000 and 3000 Series meets the demands for use in
Airports, Hotels , Hospitals, Supermarkets, Retail, Office Buildings, Public Buildings, Schools, Universities and more!

Airport & Hotels
AIRPORTS & HOTELS
Healthcare
HEALTHCARE
Supermarkets
SUPERMARKETS

 


 

OPERATIONAL FEATURES

  • Class 1 and 10 Clean Room rating for clean rooms and computer centres.
  • Wind Resistant Damper
    improves safety and reduces repair costs by withstanding wind gusts up to twice that of a standard door package.
  • Transom Packages.
  • All-Glass Doors and Sidelights provide added elegance and beauty for upscale architecture.
  • Designer/Utility package gives maximum design flexibility with wood, hollow metal, painted or full glass doors.
  • Access Control lets you add card readers, electric locks and panic hardware to limit access to restricted areas.
  • Access Control Consoles provide four modes of door operation - Timer, Manual, One-Way and Automatic.
  • Electric Solenoid Locking System utilizes a high torque stainless steel spring and tension spring.

STANLEY SU-100 MOTION SENSORS

Stanley offers the SU-100 as a standard activation system. The uni-directional function only detects approaching traffic

to reduce the length of time the door stays open, providing savings on loss of heat and air conditioning.

SAFETY SYSTEM - The Stan-Guard® threshold sensor and a doorway holding beam. The Stan-Guard® and doorway holding beam detect people or objects in the door area and holds the doors open until the threshold area is clear.

STAN-VISION™ DIGITAL SURVEILLANCE
CAMERA THAT AUTOMATES DOORS (option)

  • Safety & motion detection in one sensor.
  • Continues to detect motion when door is inactive.
  • Computer configurable sensor zones.
  • Redundant safety zone coverage.
  • Safety Zone
    Built-in diagnostics.
  • Ignores parrallel traffic.
  • IP64 waterproof rating.
  • Self-adjusts to environmental changes.
  • Fail safe operation if camera is obstructed.
  • Operates in temperatures ranging from -30° to 130° F.
  • Continuous safety coverage even while door is in motion.

 

OFFICE & PUBLIC BUILDINGS RETAIL SCHOOLS & UNIVERSITIES

 

DURA-GLIDE 2000 SERIES

 

DURA-GLIDE 3000 SERIES

Note: Transom Package Available for both 2000 & 3000 Series

 

 

FEATURES:
All models available in bi-part (double sliding) or single slide configuration.

BREAKOUT: (System is disabled when panels breakout)

DG 2000 - External Sliding Panels Only


DG 3000 - Full or All Panels Breakout


MICROPROCESSOR CONTROLLER:

— Adjustable Opening & Closing Speed
— Adjustable Distance & Speed of Breaking
— Adjustable Reduced Opening
— Adjustable Time Delay
— Auto Reverse on Obstruction
— Slow Speed Search for Obstruction

DRIVE SYSTEM:

  • ¼ HP DC Gear Driven Motor.
  • Twin ¼ HP DC Gear Driven Motors (Optional).
  • Fiberglass Reinforced Toothed Timing Belt
  • Maximum Panel Weight - Up to 400lb (with heavy duty option)
  • Door Panels : Glass, Aluminum, Wood, Metal or Custom
  • Speed Range: (based on size & weight of the door)
    — Opening Speeds: 0.5’ - 2.5’ per sec.
    — Closing Speeds: 0.5’ - 1.5’ per sec.
  • Clear Door Opening Typical Width: 3’ - 6’

Door packages are custom manufactured to fit your job requirements. For sizes greater or smaller then typical, contact your authorized Stanley Access Technologies Sales Representative.

 

 

DOOR PACKAGES ARE CUSTOM MANUFACTURED TO FIT YOUR JOB REQUIREMENTS. FOR SIZES GREATER OR SMALLER THEN TYPICAL, CONTACT YOUR STANLEY SALES REPRESENTATIVE.

 

HEADER SIZE: 8” (203mm) high x 6” (152mm) deep, 2 packages included for 12” overall depth

DOOR PACKAGE SIZE:
Standard: 116” min. width / 220.5” max. width / 7’-8” typical height
Impact: 122” min. width / 168” max. width / 7’-8” available height

IMPACT OPTION: +/- 70 psf

DOOR PANEL WEIGHT: up to 220 pounds each (100kg)

DRIVE SYSTEM: 1/4 HP DC motor standard

CONTROLLER: microprocessor based, safety logic, watchdog LED

SENSORS: 2 for motion (switchable between uni-directional and bidirectional and 1 StanGuard® and doorway holding beam for safety. Stan-Vision™ Digital Video Cameras Optional. Mats, wallplates, radio
control optional.

BREAKOUT: SX on the Entrance (when fully closed); SX panel on the Exit

POWER REQUIRED: 120 VAC, 10 amps min.

TEMPERATURE RATING: -30F to +130F

CODE COMPLIANCE: ANSI A156.10, NFPA 101, UL, cUL, IBC, ICBO, BOCA, South Florida Building Code, Miami-Dade County Compliance, NOA 03-0605.03

Example of a Bypass Door

By keeping the entry and exit doors independent, the ByPass system allows for increased and controlled pedestrian traffic flow. A continuous header for both entrance and exit doors simplifies building design. These doors provide a larger clear door opening than standard biparting doors. An impact version with a 70psf wind load rating meets Miami-Dade protocol and is available for structures withstanding hurricane force winds.